What this code means
4A 218: The flow temperature sensor has measured a temperature above 105 °C

Code 4A 218 is a locking overheating code: the flow temperature has gone above 105 °C, higher than with the 0Y codes. The boiler stops and stays blocked until a reset. Check the pressure and bleed, but leave further diagnosis to an installer; repeated resetting without a cause is pointless. Code 4A 332 has the same meaning.

Also shown as: 4A

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Flow temperature sensor, Circulation pump
Parts are model-specific; see the note below before ordering.

Common causes

  1. Severe overheating because of too little flow
  2. Air in the boiler or a seized pump
  3. Flow sensor reading incorrectly

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Note the full code and do not reset the boiler repeatedly.
  2. Check the water pressure and bleed the radiators; top up to 1.5 to 2 bar if needed.
  3. Call a CO-certified installer; at temperatures above 105 °C the cause must be found inside the boiler.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Nefit boiler. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 4A 218, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Flow temperature sensorCirculation pump

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 4A 218

What does 4A 218 mean on a Nefit boiler?

4A 218 means: The flow temperature sensor has measured a temperature above 105 °C. Code 4A 218 is a locking overheating code: the flow temperature has gone above 105 °C, higher than with the 0Y codes. The boiler stops and stays blocked until a reset. Check the pressure and bleed, but leave further diagnosis to an installer; repeated resetting without a cause is pointless. Code 4A 332 has the same meaning.

Can I fix Nefit 4A 218 myself?

Only the preliminary checks. Code 4A 218 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Nefit 4A 218?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Nefit boiler codes

See all Nefit boiler error codes